ST Series
LVDT
The ST series AC-LVDTs are layer wound on a steel coil form, providing high quality and rugged position sensors.
Featuring large radial clearance between case hole and core. Steel casing serves as electromagnetic and electrostatic shielding. Being an AC LVDT it needs a signal conditioner to operate it, such as LVDT Signal Conditioner model EL-10 or LVDT Signal Conditioner model EL-35, or LVDT Control Box CB-100 Series,
or USB-10 Unit. All are manufactured by Singer Instruments & Control.
Specifications
|
|
|
Input voltage. . . . . . . . . .
|
3Vrms (nominal)
|
|
Input Frequency . . . . . .
|
50 to 10000 Hz range, 5kHz (nominal)
|
|
Non Linearity error
|
0.25% F. R. (0.5% for ST-75, ST-100)
|
|
Operating temperature
|
-20oC to +70oC
|
|
range. . . . . . . . . . . . . . . .
|
|
Shock Survival. . . . . . . .
|
250g for 11 msec
|
|
Vibration tolerance . . . .
|
20 g up to 500 Hz
|
|
Lead wires. . . . . . . . . . . .
|
6 wires 400 mm long
|
|
|
|
Linear Range
|
Sensitivity
|
Impedance
|
Resistance
|
|
Length
|
|
|
TYPE
|
(tested at 5kHz)
|
(tested at 5kHz)
|
|
|
|
|
|
|
|
|
|
|
|
|
mm
|
V/mm/Vex
|
Ω
|
|
|
Ω
|
|
mm
|
|
|
|
|
|
|
|
|
|
Prim.
|
|
Sec.
|
Prim.
|
|
Sec.
|
A
|
|
B
|
|
|
|
|
|
|
|
|
|
|
ST-1.5
|
±1.5
|
0.18
|
220
|
|
720
|
60
|
|
170
|
30.5
|
|
21.5
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-3
|
±3
|
0.11
|
310
|
|
1200
|
95
|
|
270
|
45
|
|
25
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-5
|
±5
|
0.06
|
420
|
|
1300
|
110
|
|
260
|
74
|
|
45
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-10
|
±10
|
0.04
|
440
|
|
1500
|
90
|
|
210
|
100
|
|
65
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-25
|
±25
|
0.032
|
420
|
|
900
|
90
|
|
160
|
150
|
|
80
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-32
|
±32
|
0.03
|
450
|
|
950
|
95
|
|
170
|
160
|
|
80
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-50
|
±50
|
0.015
|
180
|
|
640
|
50
|
|
110
|
300
|
|
173
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-75
|
±75
|
0.013
|
220
|
|
800
|
60
|
|
135
|
370
|
|
185
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST-100
|
±100
|
0.01
|
280
|
|
1000
|
80
|
|
170
|
470
|
|
215
|
|
|
|